Does Wire In Attic Need To Be In Conduit

Do those need to be in conduit.
Does wire in attic need to be in conduit. What s the easiest way to identify which set of wires should go to. This is especially true when you need to curve the wires around a bend which further limits the space inside the conduit. Single conductors specified in table 310 104 a shall only be installed where part of a recognized wiring method of chapter 3. Conduit is not that expensive and can save a whole world of trouble.
Run it in conduit the whole way. Attics are susceptible to rodents especially the cute ones with fluffy tails. From there it will be ran across the ceiling joists with wood braces on each side to protect the wire s. And once in the attic the wire should travel in conduits unless very impractical.
You have to look it up. Although you can move to a larger size of conduit the larger volume may not fit in the space you have for your project. However after looking in the code book article 300 3 a states. If this is the case it may be easier to install wire without conduit.
I was also under the impression that if wiring is in an attic space that it may need to be derated because it can get very hot up there. I have seen way too much romex chewed down to the copper to trust romex where rodents could be which is going to cause me some hassle and expense. The size of all the wires. If i run se cable for the run does it need to be in conduit within the wall spaces.
Then it will drop down through the top plate and into the wall space to the flush mounted sub panel. I have always been led to believe that single strand wire needs to be run in conduit and may not be run inside the walls of a home or building. There is also a conduit fill requirement that specifies the size of the conduit vs. Really easy to forget a wire when calculating then have to upsize the.
More complicated than that. If this meets code then i will be running attic wiring in this manner from now on. Whenever i do attic wiring i remove the insulation and staple it to the ceiling joist. If the conduit is more than around 50 full with wire your conduit is too small.
One end i had the sets separated and taped terminated to 2 gfci outlets. Also i don t want to drill larger holes in the joists at least not with the exterior walls for the conduit so the conduit does not go all the way to the attic. They chew on wires. The wire running thru my attic will be 2 individual heavily insulated wires.
The other end i forgot to tape and i don t know which 3 wires black white green go to which outlet. Tk3000 oct 24 15 at 6 45.